SYNOPSIS

nvme [<global-options>] zns zone-mgmt-send <device>
                        [--namespace-id=<NUM> | -n <NUM>]
                        [--start-lba=<IONUM>, -s <IONUM>]
                        [--zsaso, -O]
                        [--select-all, -a]
                        [--zsa=<NUM>, -z <NUM>]
                        [--data-len=<IONUM>, -l <IONUM>]
                        [--data=<FILE>, -d <FILE>]

DESCRIPTION

For the NVMe device given, issues the Zone Management Send command with the requested send action. If the send requires additional data, you may specify the data length. If data is required, the input will default to stdin. Alternatively, the data may come from a file that can be specified.

OPTIONS

-n <NUM>
--namespace-id=<NUM>

Use the provided namespace id for the command. If not provided, the namespace id of the block device will be used. If the command is issued to a non-block device, the parameter is required.

-s <lba>
--start-lba=<lba>

The starting LBA of the zone to manage send.

-l <NUM>
--data-len=<NUM>

Send data buffer length

-O
--zsaso

Zone Send Action Specific Option

-a
--select-all

Send command to all zones

-z <NUM>
--zsa=<NUM>

Zone send action.

-l <IONUM>
--data-len=<IONUM>

Buffer length if data required

-d <FILE>
--data=<FILE>

Optional file for data (default stdin)

GLOBAL OPTIONS

The following options are defined at the top-level nvme command and are available to this subcommand:

--dry-run

Print the command that would be executed, but do not actually execute it.

--no-ioctl-probing

Disable probing for 64-bit IOCTL support.

--no-retries

Disable retry logic on transient errors.

-o <fmt>
--output-format=<fmt>

Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.

--output-format-version=<version>

Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names.

--timeout=<ms>

Set the timeout for the command in milliseconds.

-v
--verbose

Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

EXAMPLES

  • Send a zone management command with action set to 1 (close zone) to namespace 1’s first zone:

    # nvme zns zone-mgmt-send /dev/nvme0 -n 1 -s 0 -z 1
  • Write "hello world" into the zone descriptor for namespace 1’s first zone (requires device supports a large enough zone extended data)

    # echo "hello world" | nvme zns zone-mgmt-send /dev/nvme0 -n 1 -s 0 -z 0x10

NVME

Part of nvme-cli